FM Transmitter Measurement Report
Created: 2025-12-17 07-23-05
Measuring equipment: P75/P175/P275 |
http://pira.cz |
Station Details
| Frequency |
Signal
Reception |
Station
Name |
| 104.60 MHz |
5/5, 66 dBuV |
P3 SR |
| Pilot |
RDS |
Phase
Difference |
| 5.6 kHz |
2.4 kHz |
4 deg |
|
Frequency Deviation
| Limit |
Measuring
Tolerance |
| 75,0 kHz |
1,0 kHz |
| MIN
Hold |
Max. Samples at |
Total
Samples |
% above 76,0
kHz |
| 10 kHz |
121 kHz |
19091 |
19,6270 |
|
Modulation Power
| Limit |
Measuring
Tolerance |
| 12,0 dBr |
0,2 dBr |
| MIN |
AVE |
MAX |
% above
12,2 dBr |
| -4,2 dBr |
-2,49 dBr |
0,5 dBr |
0,0 |
|
Radio Data System
| PS |
PI |
PTY |
TP |
TA |
MS |
DI |
CT |
| "P3 SR " |
E203 |
12 (Easy M) |
0 |
1 |
1 |
9 |
6:23, 17.12.2025 |
| RT |
| "Prof. Stranger - One Last Dance With You " |
| AF |
EON |
| 97.9, 99.0, 99.4, 100.5 MHz |
E402, E424, E201 |
|
|